Radiograph
(X-ray)
X-Ray Radiography is a nondestructive semiconductor
failure analysis technique used to examine the interior details
of the package. X-Ray radiography is commonly used to inspect for
wiresweeping and other wirebond problems, die attach
voids, package voids and cracks. It is excellent
for determining leadframe outlines as well.
|
Click graphic
for larger version
|
Cross Section
Cross-sectioning or microsectioning is a
failure analysis technique for mechanically exposing a plane
of interest in a die or package for further analysis or inspection.
It usually consists of sawing, grinding, polishing, and staining
the specimen until the plane of interest is ready for optical or
electron microscopy.
De-capsulation
Decapsulation is a failure analysis step
performed to open a plastic package for internal examination.
If the package being opened is hermetic, then the process is referred
to as 'delidding' or 'decapping.' The techniques used
for decapsulation are very different from those of delidding and
decapping. Delidding/decapping is a purely mechanical process.
It may refer to the prying of the combo lid off a ceramic package,
or the application of opposite torques to the top and bottom parts
of the ceramic DIP to break the seal glass, or the cutting of the
weld around a metal can.
Scanning Electron Microscopy (S.E.M)
Scanning electron microscopy is used for
inspecting topographies of specimens at very high magnifications
using a piece of equipment called the scanning electron microscope.
SEM magnifications can go to up to 200,000 X. SEM inspection
is often used in the analysis of Die/Package Cracks, Die Attach
Failures/Defects, Bonding Failures/Defects, Wire Defects/Fractures,
Lead Defects/Failures, Foreign Materials on Die/Package, Die Surface
Defects, Seal Cracks/Defects, etc. on the die or package surface.
Code Scanning Acoustic Microscopy (C-SAM)
Scanning Acoustic Microscopy (SAM) is a
failure analysis technique used for detecting disbonds or
delaminations between package interfaces. It basically
consists of sending a sound wave through the package, and interpreting
the interaction of the sound wave with the package. The sound
wave may be generated by a piezoelectric crystal, or transducer,
that has been cut to provide a specific frequency. This wave
travels to the specimen through a medium or couplant, which is usually
deionized water since sound waves could not travel through
air at the frequencies used. The wave travels through the specimen's
material at the material's velocity, with a portion of it being
reflected back every time it hits an interface within the material.
Failure Mechanisms/Attributes Tested For: Plastic-to-Leadframe
Delamination, Plastic-to-Die Delamination, Plastic-to-Die Attach
Delamination, Die Attach Voids, Internal Cracks, etc. Internal delaminations
generally need to be addressed (especially those that occur on the
die surface and bonding fingers) because they can lead to serious
reliability issues such as neck breaks, heel breaks, and corrosion.
|
#
|
Test
|
System
|
|
1
|
HAST (High Accerated Stress Test)
|
HIRAYAMA PC422R7, EXPRESS TEST600X
|
|
2
|
Temperature Cycling (Air to Air)
|
RANSCO 7108-2, BLUE M WSP 109BMP3
|
|
3
|
Thermal Shock (Liquid to Liquid)
|
BLUE M LTB-ATS-2
|
|
4
|
THB 85/85 (Temperature Humidity Bias)
|
ESPEC PRA-4AP, ESPEC PXA-3AP
|
|
5
|
Moisture Resistance
|
ESPEC LHL112
|
|
6
|
IR Reflow, Infra Red Solder Reflow
|
HELLER 688 HAC
|
|
7
|
Centrifuge Test (Constant Acceleration)
|
CENTRISAFE G-385-4E
|
|
8
|
HTS (High Temperature Storage)
|
SES TB/2C
|
|
9
|
Gross and Fine Leak Detection
|
INTERTEST 1014-C
|
|
10
|
Physical Dimensions
|
NIKON V-12
|
|
11
|
PIND Test
|
PTI 4501M
|
|
12
|
Package Decapsulation
|
CAPT AIR 5000C
|
|
13
|
Wire Bond Pull and Ball Shear
|
DAGE 4000
|
|
14
|
Capacitance & Resistance Measurement
|
HP 4284A
|
|
15
|
Mechanical Shock Test
|
AVEX MP
|
|
16
|
Vibration Test
|
LDS
|
|
17
|
C-SAM
|
SONIX HS1000, Sonoscan D9000C
|
|
18
|
X-Ray
|
XTEC X-TEKVTX-16KV
|
|
19
|
SEM (Scanning Electron Microscopy)
|
EDAX S-2500CI
|
|
20
|
XRF (X-Ray Fluorescence)
|
TWINTEST CUPS
|
|
21
|
Laser Lead Scan
|
IS 3900DB, ICOS CI-8450
|
|
22
|
ESD and Latch-Up
|
MK2, PARAGON, KEYTEC-ZAP MASTER
|
|
23
|
CDM
|
RCDM VERIFIER
|
|
24
|
979 Fine Leak Detector(Helium)
|
Varian
|
C-Sam Imaging Modes (C-SAM)
Sonoscan - Sound Technology with Vision
|